BF-FNH type single grid series air cooled condenser has 13 varieties, rated heating exchange from 0.36-6.2kw, choose weiguang YWF series external rotor high quality motor and YZF series shaded pole motor, there are 220V/ 50HZ and 380V/50HZ two power supply parameters.
BF-FNH type double grid series air cooled condenser has 16 varieties, rated heating exchange from 5-35.6kw, choose weiguang YWF series external rotor high quality motor, the power supply is 380V/50HZ.
BF-NHA serial have more than 10 types .rated capacity: 10-80KW,Shell is made of aluminum alloy, the product installation with side and top hair hair for constant temperature and humidity high precision temperature control of the outdoor condenser.
BF-HVDK air-cooled condenser have more than 20 types, heat-exchange Surface : 50-850m2, Rated capacity: 17.4-263.5KW, can be fitted with smooth tube or Rippled tube, YWF Serial is fitted with 6-8 pmotor. Volt:380V/50Hz. Is is applicable for splifed—condensing unit.
BF-FNQ type is a kind of subwoofer air cooled condenser, has 9 varieties, rated heating exchange from 6.7-30kw, currently has been used in the outdoor unit, and the unit widely used in shopping malls, hotels, supermarkets and residential ares
TECHNICAL DATA OF FNH SERIAL AIR-COOLED CONDENSER
Model |
nominal Capacity W |
Fan motor |
inlet Diameter Φ-mm |
outlet Diameter Φ-mm |
Mounting Dimensions |
Dimensions |
||||||||
v/min Air Volume m³/h/set |
Dirof Air flow mm |
power W |
Voltage V |
quantity |
D mm Length |
E mm width |
A mm Length |
B mm width |
C mm heigth |
row×ring |
||||
(1/8)0.36/1.3 |
360 |
|
|
|
|
|
8 |
8 |
201 |
|
221 |
45 |
204 |
2×4 |
(1/4)0.56/2.4 |
670 |
|
|
|
|
|
8 |
8 |
301 |
|
321 |
45 |
204 |
2×4 |
BF-FN-0.56/2 |
560 |
270 |
170 |
22 |
220 |
1 |
8 |
8 |
270 |
70 |
290 |
110 |
215 |
2×4 |
BF-FN-0.95/3.4 |
950 |
360 |
200 |
33 |
8 |
8 |
270 |
70 |
290 |
110 |
240 |
3×4 |
||
BF-FN-1.4/4.9 |
1370 |
880 |
250 |
53 |
8 |
8 |
350 |
70 |
370 |
110 |
290 |
3×5 |
||
BF-FN-2.3/8.3 |
2320 |
1300 |
300 |
73 |
12 |
9.5 |
450 |
100 |
470 |
150 |
340 |
3×6 |
||
BF-FN-3.1/11 |
3080 |
12 |
9.5 |
450 |
100 |
470 |
150 |
340 |
4×6 |
|||||
BF-FN-2.5/9 |
2520 |
10 |
10 |
370 |
100 |
390 |
140 |
320 |
4×6 |
|||||
BF-FN-2.8/10 |
2800 |
2100 |
350 |
140 |
12 |
9.5 |
450 |
100 |
470 |
150 |
420 |
3×8 |
||
BF-FN-3.8/13.5 |
3780 |
12 |
9.5 |
450 |
125 |
470 |
175 |
420 |
4×8 |
|||||
BF-FN-4.2/15 |
4200 |
12 |
9.5 |
450 |
125 |
470 |
175 |
470 |
4×9 |
|||||
BF-FN-5.3/19 |
5320 |
3000 |
400 |
180 |
380 |
16 |
12 |
510 |
125 |
530 |
175 |
520 |
4×10 |
|
BF-FN-6.2/22 |
6200 |
16 |
12 |
510 |
170 |
530 |
220 |
520 |
5×10 |
|||||
BF-FN-5.0/18 |
5040 |
2100 |
350 |
140 |
220 |
2 |
16 |
12 |
790 |
125 |
810 |
175 |
420 |
3×8 |
BF-FN-6.7/24 |
6700 |
16 |
12 |
790 |
125 |
810 |
175 |
420 |
4×8 |
|||||
BF-FN-7.6/27 |
7560 |
16 |
12 |
790 |
125 |
810 |
175 |
470 |
4×9 |
|||||
BF-FN-10.6/38 |
10640 |
3400 |
400 |
180 |
380 |
16 |
12 |
990 |
150 |
1020 |
200 |
530 |
4×10 |
|
BF-FN-11.8/42 |
11760 |
19 |
14 |
990 |
150 |
1020 |
200 |
630 |
4×12 |
|||||
BF-FN-13.2/47 |
13160 |
19 |
14 |
990 |
170 |
1020 |
220 |
530 |
5×10 |
|||||
BF-FN-14.6/52 |
14560 |
19 |
14 |
990 |
170 |
1020 |
220 |
630 |
5×12 |
|||||
BF-FN-17.6/63 |
17640 |
22 |
16 |
990 |
170 |
1020 |
220 |
630 |
6×12 |
|||||
BF-FN-18.8/67 |
18760 |
2100 |
350 |
140 |
220 |
4 |
22 |
16 |
990 |
170 |
1020 |
220 |
830 |
4×16 |
BF-FN-21/75 |
21000 |
3400 |
400 |
180 |
380 |
22 |
16 |
990 |
170 |
1020 |
220 |
930 |
4×18 |
|
BF-FN-23.5/84 |
23520 |
22 |
16 |
990 |
170 |
1020 |
220 |
1030 |
4×20 |
|||||
BF-FN-25.8/92 |
25760 |
22 |
16 |
990 |
170 |
1020 |
220 |
1130 |
4×22 |
|||||
BF-FN-28/100 |
28000 |
25 |
19 |
990 |
170 |
1020 |
220 |
1230 |
4×24 |
|||||
BF-FN-29.4/105 |
29400 |
25 |
19 |
990 |
170 |
1020 |
220 |
1030 |
5×20 |
|||||
BF-FN-32.5/116 |
32480 |
25 |
19 |
990 |
170 |
1020 |
220 |
1130 |
5×22 |
|||||
BF-FN-35.6/127 |
35560 |
25 |
19 |
990 |
170 |
1020 |
220 |
1230 |
5×24 |
THE AIR-COOLED CONDENSER DATA OF SEMI-HERMETIC CONDENSING UNIT
Model |
nominal Capacity W |
Fan motor |
power w |
PowerSource V/P/A |
inlet Diameter(Φ-mm) |
outlet Diameter(Φ-mm) |
Dimensions |
Mounting Dimensions |
||||
Air Volume m³/h/set |
Dir ofAirflow mm |
A |
B |
H |
E |
F |
||||||
BF-FNK-03S |
7800 |
6570 |
500 |
450 |
3/380 |
19 |
16 |
886 |
203 |
715 |
160 |
775 |
BF-FNK-04S |
11150 |
6570 |
500 |
450 |
3/380 |
19 |
16 |
886 |
203 |
715 |
160 |
775 |
BF-FNK-05S |
14200 |
6570 |
500 |
450 |
3/380 |
19 |
16 |
886 |
233 |
715 |
190 |
775 |
BF-FNK-08S |
19800 |
8720 |
550 |
600 |
3/380 |
25 |
19 |
976 |
233 |
865 |
190 |
865 |
BF-FNK-10S |
26400 |
13140 |
500 |
450 |
3/380 |
25 |
19 |
1276 |
233 |
865 |
190 |
1165 |
BF-FNK-15S |
30400 |
17440 |
550 |
600 |
3/380 |
28 |
19 |
1446 |
233 |
865 |
190 |
1335 |
BF-FNK-05SH |
17750 |
6570 |
500 |
450 |
3/380 |
19 |
16 |
886 |
233 |
715 |
190 |
775 |
BF-FNK-08SH |
24750 |
8720 |
550 |
600 |
3/380 |
25 |
19 |
976 |
233 |
865 |
190 |
865 |
BF-FNK-10SH |
33000 |
13140 |
500 |
450 |
3/380 |
25 |
19 |
1276 |
233 |
865 |
190 |
1165 |
BF-FNK-15SH |
38000 |
17440 |
550 |
600 |
3/380 |
28 |
19 |
1446 |
233 |
865 |
190 |
1335 |
BF-FNK-18SH |
41800 |
17440 |
550 |
600 |
3/380 |
28 |
19 |
1446 |
233 |
965 |
190 |
1335 |
BF-FNK-20S |
45000 |
21640 |
600 |
780 |
3/380 |
28 |
22 |
1636 |
290 |
890 |
130 |
1560 |
BF-FNK-20SH |
48600 |
21640 |
600 |
780 |
3/380 |
28 |
22 |
1636 |
290 |
940 |
130 |
1560 |
BF-FNK-15ST |
54000 |
24400 |
630 |
800 |
3/380 |
28 |
19 |
1756 |
290 |
940 |
130 |
1680 |
BF-FNK-25S |
60000 |
24400 |
630 |
800 |
3/380 |
35 |
22 |
1761 |
290 |
1040 |
130 |
1680 |
BF-FNK-30S |
70500 |
26280 |
500 |
450 |
3/380 |
35 |
22 |
1641 |
290 |
1340 |
130 |
1560 |
BF-FNK-35S |
79500 |
26280 |
500 |
450 |
3/380 |
42 |
28 |
1641 |
290 |
1440 |
130 |
1560 |
BF-FNK-30SH |
90000 |
34800 |
550 |
600 |
3/380 |
35 |
22 |
1641 |
290 |
1440 |
130 |
1560 |
BF-FNK-40S |
102000 |
34800 |
550 |
600 |
3/380 |
35 |
28 |
1846 |
290 |
1440 |
130 |
1760 |
BF-FNK-35ST |
117000 |
43280 |
600 |
780 |
3/380 |
35 |
22 |
1846 |
290 |
1540 |
130 |
1760 |
BF-FNK-50S |
129000 |
43280 |
600 |
780 |
3/380 |
42 |
28 |
2139 |
290 |
1540 |
130 |
2040 |
BF-FNK-40ST |
135000 |
43280 |
600 |
780 |
3/380 |
35 |
28 |
2139 |
290 |
1590 |
130 |
2040 |
BF-FNK-50ST |
162000 |
52300 |
550 |
450 |
3/380 |
42 |
28 |
2530 |
290 |
1640 |
130 |
2430 |
Based on inlet air temperature 35 °C, condensing temperature 50 °C, inlet and outlet air temperature difference 10 °C
TECHNICAL DATA OF BF-HVDK SERIAL AIR-COOLED CONDENSER
Model |
nominal Capacity (W) |
Fan motor |
Inlet diameter (Φ-mm) |
Outlet diameter (Φ-mm) |
Mounting Dimensions |
Dimensions (mm) |
|||||||
Air Volume (m³/h) |
Dir of air flow (mm) |
Power (W) |
Voltage (0/V) |
quantity (set) |
D length (mm) |
E width (mm) |
A Length (mm) |
B width (mm) |
C height (mm) |
||||
BF-HVDK50S |
17400 |
6800 |
400 |
180 |
380 |
2 |
22 |
16 |
1020 |
557 |
1064 |
661 |
900 |
BF-HVDK60S |
19200 |
6800 |
400 |
180 |
380 |
2 |
22 |
16 |
1120 |
557 |
1164 |
661 |
900 |
BF-HVDK80S |
26080 |
9600 |
450 |
250 |
380 |
2 |
25 |
19 |
1210 |
641 |
1254 |
745 |
990 |
BF-HVDK90S |
27800 |
9600 |
450 |
250 |
380 |
2 |
25 |
19 |
1340 |
641 |
1384 |
745 |
990 |
BF-HVDK100S |
32400 |
13140 |
500 |
450 |
380 |
2 |
25 |
19 |
1460 |
641 |
1504 |
745 |
990 |
BF-HVDK120S |
36500 |
13140 |
500 |
450 |
380 |
2 |
25 |
19 |
1550 |
726 |
1594 |
830 |
1080 |
BF-HVDK140S |
44700 |
17440 |
550 |
600 |
380 |
2 |
28 |
19 |
1580 |
811 |
1624 |
915 |
1180 |
BF-HVDK150S |
46800 |
17440 |
550 |
600 |
380 |
2 |
28 |
19 |
1680 |
811 |
1724 |
915 |
1180 |
BF-HVDK162S |
53500 |
17440 |
550 |
600 |
380 |
2 |
28 |
22 |
1810 |
811 |
1854 |
915 |
1180 |
BF-HVDK180S |
60200 |
21640 |
600 |
780 |
380 |
2 |
28 |
22 |
1810 |
896 |
1854 |
1000 |
1272 |
BF-HVDK200S |
65200 |
21640 |
600 |
780 |
380 |
2 |
28 |
22 |
2010 |
896 |
2054 |
1000 |
1272 |
BF-HVDK220S |
69300 |
21640 |
600 |
780 |
380 |
2 |
32 |
22 |
2210 |
896 |
2254 |
1000 |
1272 |
BF-HVDK245S |
78600 |
26160 |
550 |
600 |
380 |
3 |
32 |
22 |
2440 |
896 |
2484 |
1000 |
1272 |
BF-HVDK275S |
84970 |
26160 |
550 |
600 |
380 |
3 |
32 |
22 |
2730 |
896 |
2773 |
1000 |
1272 |
BF-HVDK300S |
97600 |
32460 |
600 |
780 |
380 |
3 |
35 |
28 |
2960 |
896 |
3000 |
1000 |
1272 |
BF-HVDK330S |
102300 |
32460 |
600 |
780 |
380 |
3 |
42 |
28 |
2556 |
1060 |
2608 |
1165 |
1394 |
BF-HVDK360S |
109000 |
32460 |
600 |
780 |
380 |
3 |
42 |
28 |
2781 |
1060 |
2833 |
1165 |
1394 |
BF-HVDK400S |
124000 |
36600 |
630 |
800 |
380 |
3 |
42 |
28 |
2720 |
1060 |
2780 |
1165 |
1425 |
BF-HVDK450S |
135000 |
36600 |
630 |
800 |
380 |
3 |
42 |
28 |
2855 |
1060 |
2915 |
1165 |
1425 |
BF-HVDK500S |
155000 |
39420 |
500 |
450 |
380 |
6 |
42 |
32 |
2584 |
1497 |
2720 |
1547 |
1555 |
BF-HVDK550S |
170500 |
39420 |
500 |
450 |
380 |
6 |
42 |
32 |
2809 |
1497 |
2949 |
1547 |
1555 |
BF-HVDK600S |
186000 |
52320 |
550 |
600 |
380 |
6 |
42 |
32 |
2974 |
1582 |
3114 |
1632 |
1656 |
BF-HVDK650S |
198300 |
52320 |
550 |
600 |
380 |
6 |
42 |
32 |
2974 |
1582 |
3114 |
1632 |
1656 |
BF-HVDK750N |
229000 |
60000 |
550 |
370 |
380 |
8 |
54 |
35 |
3474 |
1668 |
3614 |
1718 |
1802 |
BF-HVDK850S |
263500 |
69760 |
550 |
600 |
380 |
8 |
54 |
35 |
3474 |
1668 |
3614 |
1718 |
1746 |
BF-FNQtype air cooled condenser technical parameters
Characteristics of the products:
★Fan with low speed and large blade angle, low noise .stable operation and long service life
★Big heat transfer area can greatly improve the adaptability of the ambient temperature; the fin space is large, even can be more reliable in the dusty environment
Model |
nominal Capacity W |
Fan motor |
Inlet diameter Φmm |
Outlet diameter Φmm |
Dimensions mm |
Mounting Dimensions mm |
|||||||
Air Volume m³/h |
Noise dB(A) |
Diameterx Quantity |
power W |
3N ~/V/P PowerSource |
A |
B |
H |
E1 |
E2 |
||||
BF-FNQ03/21 |
6720 |
6600 |
58 |
600x1 |
150 |
3/380/10 |
19 |
12 |
884 |
610 |
822 |
650 |
|
BF-FNQ04/30 |
9300 |
6600 |
58 |
600x1 |
150 |
3/380/10 |
19 |
12 |
884 |
610 |
822 |
650 |
|
BF-FNQ05/38 |
11780 |
6600 |
58 |
600x1 |
150 |
3/380/10 |
19 |
12 |
884 |
610 |
822 |
650 |
|
BF-FNQ06/49 |
15200 |
10600 |
60 |
700x1 |
300 |
3/380/10 |
19 |
12 |
933 |
610 |
975 |
650 |
|
BF-FNQ07/54 |
16700 |
7500 |
62 |
600x1 |
200 |
3/380/8 |
19 |
12 |
1015 |
610 |
975 |
650 |
|
BF-FNQ08/63 |
19530 |
10600 |
60 |
700x1 |
300 |
3/380/10 |
19 |
12 |
1153 |
610 |
975 |
650 |
|
BF-FNQ10/70 |
21700 |
10600 |
60 |
700x1 |
300 |
3/380/10 |
19 |
12 |
1292 |
610 |
975 |
650 |
|
BF-FNQ12/88 |
27300 |
11700 |
62 |
750x1 |
550 |
3/380/10 |
25 |
16 |
1446 |
610 |
1075 |
550 |
550 |
BF-FNQ13/97 |
30070 |
11700 |
62 |
750x1 |
550 |
3/380/10 |
25 |
16 |
1590 |
610 |
1075 |
624 |
624 |
EVAPORATION AIR-COOLED CONDENSER
ZNT SERIES EVAPORATION AIR-COOLED CONDENSER
Features of the Products
1.Adopt high technology in thermdynamics,combined the water condenser,cooling tower,recycle pump,as well as the connection tube.lt is well designed,energy and water safty, large heat exhange,smart structure.small sized.
2.On the basis of the traditional condenser,this product develops new copper tube instead of the iron tube.lt makes the overall appearance more smart,and more light, decreasing the transport and install fee.
3.The frame is good quality galvanized sheet.And painted with staticelectronic technology.lt could be errosion-proof.
4.The recycle pump is with characterstics of small power,large flow,low noise.
5.the water distribution system adopt the PVC plastic structure.the distributor is with large flow,spray evenly,long life.
6.The frame of the axial fan is Alumium alloy.and the blade is strongthen Nylon. It is with a feature of high air-flow pressure,large flow,low noise,stable.
Principle
Draining the high-temperature overheating gaseous refrigerant of compressor is from upside to inside of condensing coil, the water circulating pump send the cooling water to spray system of upside of condensing coil, then the water is sprayed uniformly on the surface of condensing coil to make water film, making heat exchange between the high-temperature overheating gaseous refrigerant inside coil and the water and air outside of coil, the refrigerant inside of coil is condensed little by little to liquid by gaseous. The refrigerant make heat spread in the process of condensing, and the spraying cool water make heat gain in the process of evaporating, make bare spraying cool water become vapor, then recycled by water trap. Unevaporated water enter water tank to be condensed by air, and fall to water trap and periodic duty. When water level of water tank was evaporated to a certain extent, ball float valve automatic opens and fill water inside of water trap.
Unit Selection procedures
1.Beifeng brand BF-ZNT serial evaporated condenser select hermetic and semi- hermetic compressor, the refrigerant is R22, R134a.
2.According to refrigerant request, select refrigeration equipment.
3.Design system total capacity=compressor refrigerant capacity + compressor motor consumed power, total capacity x modified coefficient = heat load of using working condition
4.For example: In known conditions, BFBV20-84.5 refrigerant compressor have 4pcs, working condition is -10℃/40℃, refrigeration capacity = (40480=16100)× 4pcs=226.3kw (parallel unit);
5.Using condition: condensing temperature 40℃, temperature 26℃, preview modified coefficient list to know capacity modified coefficient is 1.07
6.Counting modified coefficient capacity = total capacity × modified coefficient = 226.3x1.07=242.1kw
7.Confirming selective standard capacity ≥242.1 kw, preview product parameter list to march a ZNT-250kw evaporated condenser.
BF-ZNT SERIES EVAPORATOR TECHNICAL PARAMETERS
NO |
Model |
standard capacity KW |
Fan motor |
Pump |
inlet outlet |
||||||||
airvolume m³/h |
power KW |
voltage V |
currency A |
quantity |
flow rate m³/h |
power KW |
currency V |
current A |
inlet |
outlet |
|||
1 |
BF-ZNT-30/S |
30 |
7000 |
0. 75 |
380 |
2 |
1 |
20 |
0. 75 |
380 |
1. 81 |
28 |
19 |
2 |
BF-ZNT-50/S |
50 |
7000 |
0. 75 |
380 |
2 |
1 |
20 |
0. 75 |
380 |
1. 81 |
28 |
22 |
3 |
BF-ZNT-80/S |
80 |
10000 |
1. 1 |
380 |
2. 7 |
1 |
20 |
0. 75 |
380 |
1. 81 |
35 |
22 |
4 |
BF-ZNT-100/S |
100 |
10000 |
1. 1 |
380 |
2. 7 |
1 |
20 |
0. 75 |
380 |
1. 81 |
35 |
28 |
5 |
BF-ZNT-130/S |
130 |
10000 |
1. 1 |
380 |
2. 7 |
1 |
20 |
0. 75 |
380 |
1. 81 |
42 |
28 |
6 |
BF-ZNT-150/S |
150 |
15000 |
1.5 |
380 |
3. 7 |
1 |
25 |
1. 1 |
380 |
2. 52 |
42 |
28 |
7 |
BF-ZNT-180/S |
180 |
15000 |
1. 5 |
380 |
3. 7 |
1 |
25 |
1. 1 |
380 |
2. 52 |
54 |
28 |
8 |
BF-ZNT-200/S |
200 |
15000 |
1.5 |
380 |
3. 7 |
1 |
25 |
1. 1 |
380 |
2. 52 |
54 |
28 |
9 |
BF-ZNT-230/S |
230 |
10000 |
1. 1 |
380 |
2. 7 |
2 |
25 |
1. 1 |
380 |
2. 52 |
54 |
28 |
10 |
BF-ZNT-250/S |
250 |
10000 |
1. 1 |
380 |
2. 7 |
2 |
25 |
1. 1 |
380 |
2. 52 |
54 |
28 |
11 |
BF-ZNT-280/S |
280 |
15000 |
1. 5 |
380 |
3. 7 |
2 |
25 |
1. 1 |
380 |
2. 52 |
67 |
35 |
12 |
BF-ZNT-310/S |
310 |
15000 |
1.5 |
380 |
3. 7 |
2 |
25 |
1. 1 |
380 |
2. 52 |
67 |
35 |
13 |
BF-ZNT-330/N |
330 |
18000 |
1. 5 |
380 |
4 |
2 |
35 |
1.5 |
380 |
3.44 |
67 |
35 |
14 |
BF-ZNT-350/N |
350 |
18000 |
1.5 |
380 |
4 |
2 |
35 |
1.5 |
380 |
3.44 |
67 |
35 |
15 |
BF-ZNT-380/N |
380 |
18000 |
1. 5 |
380 |
4 |
2 |
35 |
1. 5 |
380 |
3.44 |
67 |
35 |
16 |
BF-ZNT-430/N |
430 |
21000 |
2.2 |
380 |
5.6 |
2 |
35 |
1.5 |
380 |
3.44 |
76 |
42 |
17 |
BF-ZNT-480/N |
484 |
21000 |
2. 2 |
380 |
5. 6 |
2 |
35 |
1. 5 |
380 |
3.44 |
76 |
42 |
18 |
BF-ZNT-530/N |
530 |
21000 |
2.2 |
380 |
5.6 |
2 |
35 |
1.5 |
380 |
3.44 |
76 |
42 |
19 |
BF-ZNT-580/N |
580 |
30000 |
3 |
380 |
7 |
2 |
50 |
2.2 |
380 |
4. 74 |
76 |
42 |
20 |
BF-ZNT-630/N |
630 |
30000 |
3 |
380 |
7 |
2 |
50 |
2.2 |
380 |
4. 74 |
76 |
42 |
21 |
BF-ZNT-680/N |
680 |
30000 |
3 |
380 |
7 |
2 |
50 |
2.2 |
380 |
4. 74 |
76 |
42 |
22 |
BF-ZNTG-800/N |
800 |
45000 |
4 |
380 |
9 |
2 |
70 |
3 |
380 |
7 |
2×89 |
2×76 |
23 |
BF-ZNTG-950/N |
950 |
60000 |
4 |
380 |
9 |
2 |
70 |
3 |
380 |
7 |
2×114 |
2×89 |
24 |
BF-ZNTG-1100/N |
1100 |
71000 |
5.5 |
380 |
11 |
2 |
70 |
3 |
380 |
7 |
2×114 |
2×89 |
25 |
BF-ZNTG-1200/N |
1200 |
40000 |
3 |
380 |
7 |
3 |
78 |
3 |
380 |
7 |
3×89 |
3×76 |
26 |
BF-ZNTG-1400/N |
1400 |
80000 |
5.5 |
380 |
11 |
2 |
129 |
5.5 |
380 |
11 |
2×114 |
2×89 |
27 |
BF-ZNTG-1600/N |
1600 |
60000 |
5. 5 |
380 |
11 |
4 |
129 |
5. 5 |
380 |
11 |
4×89 |
4×76 |
SERIAL EVAPORATED CONDENSER EXTERNAL DIMENSIONS
Model
|
external dimension |
mountinq dimension |
mouting conneltrg pipe |
|||||||
A mm |
B mm |
C mm |
D mm |
E mm |
El mm |
E2 mm |
water replenishint Φmm |
return tube Φmm |
drainage pipe Φmm |
|
BF-ZNT-30/S |
1284 |
957 |
2540 |
897 |
138 |
696 |
|
1" |
2. 5" |
2" |
BF-ZNT-50/S |
1284 |
957 |
2540 |
897 |
138 |
696 |
|
1" |
2. 5" |
2" |
BF-ZNT-80/S |
1384 |
1230 |
2540 |
1170 |
138 |
780 |
|
1" |
2. 5" |
2" |
BF-ZNT-100/S |
1384 |
1230 |
2620 |
1170 |
138 |
780 |
|
1" |
2. 5" |
2" |
BF-ZNT-130/S |
1384 |
1230 |
2620 |
1170 |
138 |
780 |
|
1" |
2. 5" |
2" |
BF-ZNT-150/S |
1734 |
1230 |
2620 |
1170 |
138 |
1146 |
|
1" |
2. 5" |
2" |
BF-ZNT-180/S |
1734 |
1230 |
2620 |
1170 |
138 |
1146 |
|
1" |
2. 5" |
2" |
BF-ZNT-200/S |
1734 |
1230 |
2620 |
1170 |
138 |
1146 |
|
1" |
2. 5" |
2" |
BF-ZNT-230/S |
2204 |
1230 |
2620 |
1170 |
138 |
808 |
808 |
1" |
2. 5" |
2" |
BF-ZNT-250/S |
2204 |
1230 |
2620 |
1170 |
138 |
808 |
808 |
1" |
2. 5" |
2" |
BF-ZNT-280/S |
2204 |
1230 |
2620 |
1170 |
138 |
808 |
808 |
1" |
2. 5" |
2" |
BF-ZNT-310/S |
2204 |
1230 |
2620 |
1170 |
138 |
808 |
808 |
1" |
2. 5" |
2" |
BF-ZNT-330/N |
2534 |
1433 |
2650 |
1373 |
138 |
970 |
970 |
1" |
2. 5" |
2" |
BF-ZNT-350/N |
2534 |
1433 |
2650 |
1373 |
138 |
970 |
970 |
1" |
2. 5" |
2" |
BF-ZNT-380/N |
2534 |
1433 |
2650 |
1373 |
138 |
970 |
970 |
1" |
2. 5" |
2" |
BF-ZNT-430/N |
2534 |
1433 |
2650 |
1373 |
138 |
970 |
970 |
1" |
2. 5" |
2" |
BF-ZNT-480/N |
2714 |
1433 |
2650 |
1373 |
138 |
1068 |
1068 |
1" |
2. 5" |
2" |
BF-ZNT-530/N |
2714 |
1433 |
2650 |
1373 |
138 |
1068 |
1068 |
1" |
2. 5" |
2" |
BF-ZNT-580/N |
3034 |
1671 |
2730 |
1610 |
138 |
1220 |
1220 |
1" |
2. 5" |
2" |
BF-ZNT-630/N |
3034 |
1671 |
2730 |
1610 |
138 |
1220 |
1220 |
1" |
2. 5" |
2" |
BF-ZNT-680/N |
3034 |
1671 |
2730 |
1610 |
138 |
1220 |
1220 |
1" |
2. 5" |
2" |
BF-ZNTG-800/N |
3490 |
2000 |
3290 |
\ |
\ |
\ |
\ |
1" |
2. 5" |
2" |
BF-ZNTG-950/N |
3810 |
2100 |
3730 |
\ |
\ |
\ |
\ |
1" |
2. 5" |
2" |
BF-ZNTG-1100/N |
4420 |
2100 |
3700 |
\ |
\ |
\ |
\ |
1" |
2. 5" |
2" |
BF-ZNTG-1200/N |
4520 |
2200 |
3600 |
\ |
\ |
\ |
\ |
1" |
2. 5" |
2" |
BF-ZNTG-1400/N |
4420 |
2550 |
3750 |
\ |
\ |
\ |
\ |
1" |
2. 5" |
2" |
BF-ZNTG-1600/N |
5870 |
2200 |
3600 |
\ |
\ |
\ |
\ |
1" |
2. 5" |
2" |
R22 AND R134a HEAT-EXTRACTION SYSTEM
cordensinq pressure (kPa) |
condensation temperature |
air mtake wetbulb temperature |
||||||||||||||||||
℃ |
||||||||||||||||||||
R22 |
R134a |
℃ |
10 |
12 |
14 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
23 |
24 |
25 |
26 |
27 |
28 |
29 |
30 |
1191 |
771 |
30 |
1.05 |
1.13 |
1.23 |
1.38 |
1.45 |
1.54 |
1.65 |
1.79 |
1.95 |
2.25 |
2.44 |
2.78 |
3.28 |
|
|
|
|
|
1254 |
815 |
32 |
0.94 |
1 |
1.08 |
1.17 |
1.23 |
1.3 |
1.37 |
1.5 |
1.62 |
1.76 |
1.93 |
2.1 |
2.35 |
2.6 |
|
|
|
|
1320 |
862 |
34 |
0.84 |
0.9 |
0.97 |
1.04 |
1.1 |
1.15 |
1.2 |
1.27 |
1.34 |
1.44 |
1.55 |
1.66 |
1.8 |
1.99 |
2.19 |
2.5 |
|
|
1355 |
887 |
35 |
0.8 |
0.85 |
0.91 |
0.97 |
1.02 |
1.06 |
1.1 |
1.17 |
1.24 |
1.3 |
1.37 |
1.46 |
1.55 |
1.72 |
1.91 |
2.14 |
2.41 |
2.77 |
1390 |
912 |
36 |
0.77 |
0.81 |
0.86 |
0.92 |
0.96 |
1 |
1.04 |
1.07 |
1.13 |
1.19 |
1.26 |
1.34 |
1.42 |
1.53 |
1.69 |
1.89 |
2.14 |
2.38 |
1461 |
963 |
38 |
0.7 |
0.74 |
0.78 |
0.82 |
0.85 |
0.88 |
0.9 |
0.93 |
0.96 |
1.01 |
1.06 |
1.12 |
1.17 |
1.25 |
1.35 |
1.47 |
1.62 |
1.78 |
1537 |
1016 |
40 |
0.65 |
0.67 |
0.7 |
0.73 |
0.76 |
0.78 |
0.8 |
0.83 |
0.86 |
0.89 |
0.93 |
0.97 |
1.01 |
1.07 |
1.13 |
1.2 |
1.3 |
1.43 |
1610 |
1072 |
42 |
0.59 |
0.61 |
0.64 |
0.67 |
0.68 |
0.7 |
0.72 |
0.74 |
0.77 |
0.8 |
0.83 |
0.86 |
0.89 |
0.93 |
0.98 |
1.04 |
1.1 |
1.18 |
1689 |
1130 |
44 |
0.54 |
0.56 |
0.58 |
0.6 |
0.62 |
0.63 |
0.65 |
0.66 |
0.68 |
0.7 |
0.73 |
0.76 |
0.78 |
0.82 |
0.85 |
0.89 |
0.93 |
0.97 |
Honesty is the basis, win-win through cooperation
Copyright © 2018 Zhejiang Beifeng Refrigeration Equipment Co., Ltd. All Rights Reserved. Technical Support : HWAQ