Box Type Chiller

Box Type Chiller

Contact Us

Details

SEMI-HERMETIC INDUSTRIAL CHILLER

UINHT MODEL INSTRUCTION

AIR-COOLED CHILLER TECHNICAL PARAMETERS

 

Model Parameter

BF-LSBF04

BF-LSBF05

BF-LSBF08

BF-LSBF10

BF-LSBF15

BF-LSBF20

BF-LSBF30

BF-LSBF35

BF-LSBF40

BF-LSBF50

BF-LSBF60

BF-LSBF80

Refrigerating effect Kw 

10.6

15.1

19.5

28.1

41.9

42.1

61.3

80.4

92.1

108.8

122.6

184.2

Total power Kw

4.51

5.53

7.71

11.49

15.76

15.59

23.26

28.64

33.45

41.99

45.44

66.9

Max. running current A

7.6

10.1

15

17.6

24.3

37

53

61

78

92

106

156

Power supply

3PH/380V/50HZ

Refrigerant throttling mode

Heat expansion valve

Refrigerant

R22

Refrigerating circuit

1

1

1

1

1

1

1

1

1

1

2

2

Compressors

 

Style

Semi-closed piston type

Model

BFBZ4

15H

BFBZ5

18H

BFBZ8

27H

BFBZ10

36H

BFBZ15

54H

BFBV20

56H

BFBV30 84. 5H

BFBW35 110. 5H

BFBW40 126. 8H

BFBW50 151.6H

BFBV30 84. 5H

BFBW40 126. 8H

Power Kw 

4.15

5.03

6.81

10.29

14.2

14.03

20.92

26.24

31.05

38.39

41.84

62.1

Quantity

1

1

1

1

1

1

1

1

1

1

2

2

Condenser

 

Form

Copper-tube aluminum-fin type

Model

BF-

NCH/0500

BF-

NCH/0500

BF-

NCH/1000

BF-

NCH/1000

BF-

NCH/1500

BF-

NCH/2000

BF-

NCH/3000

BF-

NCH/4000

BF-

NCH/4000

BF-

NCH/5000

BF-

HVDK500

BF-

HVDK750N

Fan Power Kw

0.36

0.36

0.90

0.9

1.2

1.56

2.5

2.40

2.40

3.12

2.22

2.96

Fan Delivery m³/h

6300

6300

12600

12600

16660

21000

31500

33320

33320

47000

45000

60000

Evaporator

Form

High-efficiency shell and tube type heat exchanger

Secondary Refrigerant

Water, glycol

Inlet Temperature ℃

+ 12

Outlet Temperature ℃

+ 7

Rate of Flow m³/h

2.4

3.0

3.6

5.4

8.1

8.5

12.1

15.1

18.1

21.2

24.2

36.2

Specification of connecting pipe

1-1/2"

1-1/2"

1-1/2"

1-1/2"

2"

2"

2"

2-1/2"

2-1/2"

2-1/2"

3"

3"

Running control mode

Fully automatic

Safety protection device

The assembly unit has overload protection, the compressor has overheat protection. High and low pressure, oil pressure protection; open-phase protection; ultralow water temperature protection; flow rate protection.

 

Remarks:

The working conditions of assembly unit under nominal refrigerating effect and power: condensing temperature 50℃, inlet water temperature +12℃, outlet water temperature +7℃

 

WATER-COOLED CHILLER TECHNICAL PARAMETERS

 

Model Parameter

BF-LSB04

BF-LSB05

BF-LSB08

BF-LSB10

BF-LSB15

BF-LSB20

BF-LSB30

BF-LSB35

BF-LSB40

BF-LSB50

BF-LSB60

BF-LSB100

Refrigerating effect Kw 

11.2

15

21.6

29.3

43.2

47.9

69.5

89.8

102.8

122.8

139

245.6

Total power Kw

3.58

4.48

6.07

9.11

12.11

12.34

18.16

22.82

26.99

33.18

36.32

66.36

Max. running current A 

7.6

10.1

15

17.6

24.3

37

53

61

78

92

106

184

Power supply

3PH/380V/50HZ

Refrigerant throttling mode

Heat expansion valve

Refrigerant

R22

Refrigerating circuit

1

1

1

1

1

1

1

1

1

1

2

2

Compressors

Style

Semi-closed piston type

Model

BFBZ4

15H

BFBZ5

18H

BFBZ8

27H

BFBZ10

36H

BFBZ15

54H

BFBV20

56H

BFBV30

84.5H

BFBW35

110.5H

BFBW40 126.8H

BFBW50 151.6H

BFBV30

84.5H

BFBW50

151.6H

Quantity

1

1

1

1

1

1

1

1

1

1

2

2

Form

High-efficiency shell and tube type heat exchanger

Condenser

 

Inlet water temperature ℃

30

Outlet water temperature ℃

 

 

 

 

 

3

5

 

 

 

 

 

Flow rate of cooling water m³/h

3

3.8

5.4

7.2

10.8

12.1

17.1

22.3

25.6

30.2

34.2

60.4

Specification of connecting pipe

1-1/2"

1-1/2"

1-1/2"

2"

2"

2"

2-1/2"

2-1/2"

2-1/2"

2-1/2"

3"

4"

Evaporator

 

Form

High-efficiency shell and tube type heat exchanger

Secondary Refrigerant

Water, glycol

Inlet Temperature ℃

+ 12

 Outlet Temperature℃

+ 7

Rate of Flow m³/h 

2.4

3.0

4.8

6.1

8.6

9.1

13.3

16.9

19.7

23.2

26.6

46.4

Specification of connecting pipe

1-1/2"

1-1/2"

1-1/2"

1-1/2"

2"

2"

2-1/2"

2-1/2"

3"

3"

3"

4"

Running control mode

 Fully automatic

Safety protection device