Air-Cooled Condensers Manufacturers

Zhejiang Beifeng Refrigeration Equipment Co., Ltd. has 35 years history of manufacturing refrigeration equipment. Currently, it has two processing bases located in Shengzhou, Zhejiang, with a production building of 60,000 square meters. It has set up three sales companies in Shanghai, Beijing, and Guangzhou, with strong technical force, advanced equipment, complete varieties and stable quality. As a leading China Air-Cooled Condensers manufacturers and Air-Cooled Condensers suppliers, We have a variety of condenser, evaporator production mold, heat transfer from 0.36 to 263.5 kw, We have a strong technical team,and we can develop and produce products according to the drawings or samples the customers offered. The company has a high-quality inspection center to detect the performance index of custom Air-Cooled Condensers and imported vacuum-type helium leak detectors for condensers and evaporators. It has a great influence in the national refrigeration industry and occupies a large market, with distributors in all major cities; It enjoys a high reputation not only in the domestic market, but also in the overseas market, and the products are exported to Europe, Southeast Asia, the Middle East, North America, Africa, etc.

Since 1986

Professional refrigeration equipment manufacturer

Zhejiang Beifeng Refrigeration Equipment Co., Ltd. has 35 years history of manufacturing refrigeration equipment. Currently, it has two processing bases located in Shengzhou, Zhejiang, with a production building of 60,000 square meters. It has set up three sales companies in Shanghai, Beijing, and Guangzhou, with strong technical force, advanced equipment, complete varieties and stable quality. The company has a high-quality inspection center to detect the performance index of refrigeration products and imported vacuum-type helium leak detectors for condensers and evaporators. It has a great influence in the national refrigeration industry and occupies a large market, with distributors in all major cities; It enjoys a high reputation not only in the domestic market, but also in the overseas market, and the products are exported to Europe, Southeast Asia, the Middle East, North America, Africa, etc.

Zhejiang Beifeng Refrigeration Equipment Co., Ltd.

Follow Beifeng to get the latest enterprise and refrigeration equipment products news

What’s New

Industry knowledge extension of this category

Installation and Maintenance of Air-Cooled Condensers
The installation of air-cooled condensers requires careful planning and consideration to ensure that they perform efficiently and reliably throughout their service life. Several factors need to be accounted for before the installation process begins, such as the location, environmental conditions, and the specific requirements of the system. These units rely on airflow to expel heat, so the installation site must have sufficient space for air circulation around the unit. The condenser needs an unobstructed path for air intake and exhaust. Obstructions such as walls, other equipment, or excessive vegetation can impede airflow, reducing the unit's cooling capacity and energy efficiency. The condenser should be located away from heat sources such as exhaust vents, direct sunlight, or other equipment that generates heat. The surrounding temperature directly impacts the condenser's cooling efficiency. Maintenance personnel should have easy access to the condenser for routine maintenance, cleaning, and repairs. The installation location should not be too difficult to reach or too far from power sources and refrigerant piping connections. Zhejiang Beifeng Refrigeration Equipment Co., Ltd. ensures that their air-cooled condensers come with clear and comprehensive installation guidelines, which consider these factors and promote efficient operation. Their experienced engineers can offer expert advice on the ideal placement of condensers based on the specific needs of the client’s cooling system.

Once the location has been chosen and the surface has been prepared, the installation of an air-cooled condenser can begin. The following are the key steps involved in installing the unit: The air-cooled condenser should be positioned according to the manufacturer’s guidelines. It is crucial to maintain the correct orientation to ensure proper airflow and optimal heat dissipation. Special attention should be paid to the positioning of the fans and coils, as improper alignment can affect the condenser’s performance. After positioning the unit, the refrigerant piping must be connected to the condenser. This involves linking the discharge line from the compressor to the condenser inlet and the outlet of the condenser to the evaporator or the expansion valve, depending on the system configuration. It is essential to ensure that the piping is correctly sized and installed to avoid leaks or inefficiencies. Once the piping is connected, it is crucial to perform leak testing to ensure the system is sealed properly. Zhejiang Beifeng Refrigeration Equipment Co., Ltd. uses high-quality inspection tools, including imported vacuum-type helium leak detectors, to detect any leaks in their condensers before shipment, guaranteeing that customers receive fully functional units.Zhejiang Beifeng Refrigeration Equipment Co., Ltd. emphasizes the importance of a detailed testing phase. Their air-cooled condensers undergo rigorous performance checks at their manufacturing facilities to ensure that customers receive top-quality products ready for installation.

Maintaining an air-cooled condenser is crucial for its continued performance and longevity. Regular maintenance not only ensures that the unit operates at peak efficiency but also helps identify potential issues before they lead to expensive repairs or system breakdowns. One of the most important aspects of maintaining an air-cooled condenser is keeping it clean. The condenser’s fins and coils can become clogged with dirt, dust, and debris, which can impede airflow and reduce the unit’s ability to dissipate heat. Regular cleaning should be done, especially if the condenser is installed in a dusty or dirty environment. The fins on the condenser coils can accumulate debris, leading to reduced heat transfer. These fins should be cleaned regularly using a soft brush or compressed air. Avoid using harsh chemicals or brushes that could damage the fins. Ensure that the airflow pathways are free of obstructions such as leaves, dirt, or even ice. The fans should be inspected regularly to ensure they are free from blockages and running efficiently.Zhejiang Beifeng Refrigeration Equipment Co., Ltd. provides customers with comprehensive maintenance guides and offers support services to ensure that their air-cooled condensers continue to operate optimally over time. Their high-quality inspection centers enable them to perform rigorous testing of the products before shipment to ensure long-term reliability.

Over time, air-cooled condensers may experience a drop in refrigerant levels due to leaks or system wear. Low refrigerant levels can reduce the condenser's cooling efficiency and put unnecessary strain on the system. It is essential to periodically check refrigerant levels and recharge the system when necessary. If a drop in refrigerant levels is detected, it is essential to locate the source of the leak. Using helium leak detectors, like those used by Zhejiang Beifeng Refrigeration Equipment Co., Ltd., ensures that any leaks are accurately detected and addressed before they lead to system failure. In addition to routine cleaning and inspections, an annual service check by a qualified technician can help maintain the efficiency and longevity of the condenser. This service includes a comprehensive inspection of all components, a refrigerant level check, and a full system performance test. Zhejiang Beifeng Refrigeration Equipment Co., Ltd. offers post-sale services to ensure their air-cooled condensers remain in top condition throughout their operational lifespan, supporting both local and international customers with professional servicing and maintenance advice.